Rental Products
> Safety Valve Test Stand
|
<< Return
|
Safety Valve Test Stand
|
The Nu-Tec SVTS allows testing of all safety valves out of the critical path and requires no rig tongs for makeup due to its designed Nu-Tec Seal Groove. The SVTS has a working pressure of 15,000 PSI. Our standard SVTS come standard with a 4 ½ IF box and a 2" 1502 Weco. Nu-Tec has a full line of Crossovers to get you back to the connection you are using
|
Single Safety Valve Test Stand |
Double Safety Valve Test Stand |
|

|

|
|
4-way Safety Valve Test Stand |
|

|
|
6-way Safety Valve Test Stand |
|

|
Procedure for installing and using a Safety Valve Test Stand
-
Install the test stand on the rig floor close to the cement pump line and away from the rotary work area.
-
Weld the base to the deck. One inch welds on each corner will hold the stand in place.
-
Make sure the BOTTOM TEST SUB is tight on the base.
-
Connect the cement pump to the 1502 WECO.
-
Insure that the ring groove on the test sub is clean and dry. Install a Nu-Tec Seal in the ring groove and apply pipe dope AFTER the Nu-Tec Seal is installed. The Nu-Tec Seal should last for 6 to 8 tests – Replace each week or as required.
-
Install the Safety Valve or Inside BOP safety valve in the BOTTOM TEST SUB and tighten with large chain tongs. DO NOT USE RIG TONGS.
-
Test the Safety Valve or Inside BOP Valves to a low and high pressure. |
|
|
|
| |